36 kV three-phase distribution transformers — 50 to 3,150 kVA
Range image — configuration depends on the selected rating and options.
At a glance
These three-phase distribution transformers transfer power from the medium-voltage network to the supplied installation. The range covers 50–3,150 kVA; the 36 kV class identifies the insulation level, not the secondary voltage.
- Transformer type
- MV/LV power distribution — three-phase, oil-immersed
- Rated power
- 50 to 3,150 kVA
- Voltage class
- 36 kV
- Available primary voltages
- 30 / 31.5 / 33 / 34.5 kV
Price, packaging and lead time confirmed for your quantity and destination.
View my selection and send the enquiry ↗The product in detail
These three-phase distribution transformers transfer power from the medium-voltage network to the supplied installation. The range covers 50–3,150 kVA; the 36 kV class identifies the insulation level, not the secondary voltage.
Fully filled hermetic or breathing construction is available according to the project. Bushings, off-circuit tap changer, handling fittings and protection are specified with the ordered configuration.
The function is to supply loads through power transfer. Specify kVA rating, operating voltages, vector group and protection to define the ordered configuration.
Applications
- Distribution substations
- Industrial power supplies
- Medium- and low-voltage networks
For a tailored quotation
Specify kVA rating, primary and secondary voltages, vector group, frequency, installation conditions and protection. Tabulated dimensions and weights are indicative: confirm the execution drawing for the ordered configuration.
Contact our team ↗Specifications
| Transformer type | MV/LV power distribution — three-phase, oil-immersed |
|---|---|
| Rated power | 50 to 3,150 kVA |
| Voltage class | 36 kV |
| Available primary voltages | 30 / 31.5 / 33 / 34.5 kV |
| Secondary voltage | To be specified for the network and project |
| Frequency | 50 / 60 Hz |
| Standard | IEC 60076 |
| Cooling | ONAN — natural oil and air circulation |
| Dielectric | Mineral oil to IEC 60296 |
| Windings | Copper; aluminium optional |
| Installation | Indoor or outdoor |
| Finish | RAL 7035; C5H corrosion protection |
| Connection and protection options | MV plug-in bushings and connectors, surge arresters, covers, DMCR or DGPT2 |
References and variants
Compare dimensions and configurations, then choose the variant for your quotation.
16 variants
| Reference / variant | Specifications | Quotation |
|---|---|---|
| 50 kVA | uₖ 4.5 % · L × W × H: 950 × 700 × 1290 mm · Total weight: 550 kg | |
| 100 kVA | uₖ 4.5 % · L × W × H: 1100 × 720 × 1250 mm · Total weight: 640 kg | |
| 160 kVA | uₖ 4.5 % · L × W × H: 1150 × 840 × 1370 mm · Total weight: 770 kg | |
| 200 kVA | uₖ 4.5 % · L × W × H: 1200 × 850 × 1390 mm · Total weight: 1030 kg | |
| 250 kVA | uₖ 4.5 % · L × W × H: 1290 × 860 × 1400 mm · Total weight: 1060 kg | |
| 315 kVA | uₖ 4.5 % · L × W × H: 1400 × 950 × 1430 mm · Total weight: 1260 kg | |
| 400 kVA | uₖ 4.5 % · L × W × H: 1380 × 880 × 1500 mm · Total weight: 1460 kg | |
| 500 kVA | uₖ 4.5 % · L × W × H: 1420 × 920 × 1550 mm · Total weight: 1590 kg | |
| 630 kVA | uₖ 4.5 % · L × W × H: 1600 × 1020 × 1580 mm · Total weight: 1950 kg | |
| 800 kVA | uₖ 5 % · L × W × H: 1750 × 1100 × 1750 mm · Total weight: 2450 kg | |
| 1000 kVA | uₖ 5.5 % · L × W × H: 1900 × 1170 × 2000 mm · Total weight: 2900 kg | |
| 1250 kVA | uₖ 6 % · L × W × H: 1950 × 1200 × 2000 mm · Total weight: 3400 kg | |
| 1600 kVA | uₖ 6.5 % · L × W × H: 2130 × 1450 × 1900 mm · Total weight: 4400 kg | |
| 2000 kVA | uₖ 7 % · L × W × H: 2450 × 1400 × 2230 mm · Total weight: 5950 kg | |
| 2500 kVA | uₖ 7.5 % · L × W × H: 2680 × 1520 × 2620 mm · Total weight: 7040 kg | |
| 3150 kVA | uₖ 7.5 % · L × W × H: 2900 × 1560 × 2800 mm · Total weight: 8850 kg |
Your export quotation for 36 kV three-phase distribution transformers — 50 to 3,150 kVA
State your requirements, quantities and receiving country for a tailored quotation.
Request a quotation for this reference →