- Rated voltage
- 0.6 / 1 kV
- Listed dielectric withstand
- 6 kV in water
- Listed standards
- NFC33-020 / EN 50483-4
- Materials
- Aluminium-alloy or tinned-copper-alloy contact blades
Price, packaging and lead time confirmed for your quantity and destination.
View my selection and send the enquiry ↗The product in detail
Low-voltage network-to-network joint or branch connector. Several main/branch cross-section combinations are available according to the connector designation.
CDRS/CT95-70 — Main 35-95 mm²; branch 16-70 mm²; aluminium alloy; torque 14 N·m
CDRS/CT70-70 — Main 35-70 mm²; branch 35-70 mm²; aluminium alloy; torque 14 N·m
CDRS/CT70-70 — Main 16-70 mm²; branch 16-70 mm²; aluminium alloy; torque 14 N·m
CDRS/CT95-95 — Main 16-95 mm²; branch 16-95 mm²; aluminium alloy; torque 14 N·m
CDRS/CT70-70 — Main 35-70 mm²; branch 35-70 mm²; tinned copper alloy; torque 14 N·m
CDRS/CT70-70 — Main 16-70 mm²; branch 16-70 mm²; tinned copper alloy; torque 14 N·m
CDRS/CT95-70 — Main 35-95 mm²; branch 16-70 mm²; tinned copper alloy; torque 14 N·m
CDRS/CT95-95 — Main 16-95 mm²; branch 16-95 mm²; tinned copper alloy; torque 14 N·m
Applications
- Low-voltage overhead networks
- Insulated conductor connections
For a tailored quotation
Specify the reference, conductor type and cross-section, network voltage, required mechanical loads, quantity and destination. Confirm assembly compatibility and the offered version with the quotation.
Contact our team ↗Specifications
| Reference | CPL95 |
|---|---|
| Rated voltage | 0.6 / 1 kV |
| Listed dielectric withstand | 6 kV in water |
| Listed standards | NFC33-020 / EN 50483-4 |
| Materials | Aluminium-alloy or tinned-copper-alloy contact blades |
| Configurations | 95/70, 70/70 or 95/95 according to the listed ranges |
| Tightening torque | 14 N·m |
References and variants
Compare dimensions and configurations, then choose the variant for your quotation.
8 variants
| Reference / variant | Specifications | Quotation |
|---|---|---|
| CDRS/CT95-70 | Main 35-95 mm²; branch 16-70 mm²; aluminium alloy | |
| CDRS/CT70-70 | Main 35-70 mm²; branch 35-70 mm²; aluminium alloy | |
| CDRS/CT70-70 | Main 16-70 mm²; branch 16-70 mm²; aluminium alloy | |
| CDRS/CT95-95 | Main 16-95 mm²; branch 16-95 mm²; aluminium alloy | |
| CDRS/CT70-70 | Main 35-70 mm²; branch 35-70 mm²; tinned copper alloy | |
| CDRS/CT70-70 | Main 16-70 mm²; branch 16-70 mm²; tinned copper alloy | |
| CDRS/CT95-70 | Main 35-95 mm²; branch 16-70 mm²; tinned copper alloy | |
| CDRS/CT95-95 | Main 16-95 mm²; branch 16-95 mm²; tinned copper alloy |