Ormazabal cgm.3-2lp — Compact medium-voltage (MV) switchgear — Two lines and fuse protection
Ref. cgm.3-2lp
Reference: RM6
Manufacturer cutaway view of an RM6 board; configuration example.
Schneider Electric RM6 is compact medium-voltage (MV) switchgear for electrical distribution substations. Function: Configurable compact MV switchgear.
Price, packaging and lead time confirmed for your quantity and destination.
View my selection and send the enquiry ↗Schneider Electric RM6 is compact medium-voltage (MV) switchgear for electrical distribution substations. Function: Configurable compact MV switchgear.
Functions I, B, D, Q, Ic, Bc and O combine to suit the substation diagram. Mt / DE-Mt and AA-10 metering modules complement selected configurations and have separate connection and dimensional requirements. Function letters are not complete ordering codes.
State the network voltage, single-line diagram, current ratings, short-circuit duty, protection and room dimensions. Configuration, options, suitability for the destination network and lead time are confirmed with the quotation.
State the network voltage, single-line diagram, current ratings, short-circuit duty, protection and room dimensions. Configuration, options, suitability for the destination network and lead time are confirmed with the quotation.
Contact our team ↗| Brand | Schneider Electric |
|---|---|
| Reference | RM6 |
| Product type | Compact medium-voltage (MV) switchgear |
| Range | RM6 |
| Function | Configurable compact MV switchgear |
| Rated voltage | 12 / 17.5 / 24 kV |
| Frequency | 50 / 60 Hz |
| Main switchgear insulation | SF6 gas; DE-Mt metering cubicle is air-insulated |
Compare dimensions and configurations, then choose the variant for your quotation.
10 variants
| Reference / variant | Specifications | Quotation |
|---|---|---|
| I | 630 A network switch | |
| B | 630 A line circuit breaker | |
| D | 200 A transformer circuit breaker | |
| Q | Switch-fuse combination | |
| Ic | Bus coupler switch | |
| Bc | 630 A bus coupler circuit breaker | |
| O | Cable connection | |
| Mt / DE-Mt | Busbar metering — air-insulated cubicle | |
| AA-10 | Feeder metering — compact module | |
| Extensibility | NE: non-extensible; RE: right; LE: left; DE: both sides, depending on combination |